Sample Name	Protocol REF	Comment[ADNI protocol]	Parameter Value[instrument]	Parameter Value[manufacturer]	Parameter Value[magnetic field strength]	Assay Name	Raw Data File	Comment[Data Repository]	Comment[Data Record Accession]	Comment[Data Record URL]	Protocol REF	Derived Data File	Comment[Data Repository]	Comment[Data Record Accession]	Comment[Data Record URL]	Comment[additional files]
Subject1Scan1	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan1	test-retest_data_July_2014/brain_data/Subject_1/T1_01.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan2	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan2	test-retest_data_July_2014/brain_data/Subject_1/T1_02.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan3	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan3	test-retest_data_July_2014/brain_data/Subject_1/T1_03.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan4	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan4	test-retest_data_July_2014/brain_data/Subject_1/T1_04.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan5	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan5	test-retest_data_July_2014/brain_data/Subject_1/T1_05.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan6	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan6	test-retest_data_July_2014/brain_data/Subject_1/T1_06.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan7	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan7	test-retest_data_July_2014/brain_data/Subject_1/T1_07.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan8	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan8	test-retest_data_July_2014/brain_data/Subject_1/T1_08.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan9	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan9	test-retest_data_July_2014/brain_data/Subject_1/T1_09.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan10	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan10	test-retest_data_July_2014/brain_data/Subject_1/T1_10.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan11	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan11	test-retest_data_July_2014/brain_data/Subject_1/T1_11.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan12	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan12	test-retest_data_July_2014/brain_data/Subject_1/T1_12.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan13	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan13	test-retest_data_July_2014/brain_data/Subject_1/T1_13.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan14	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan14	test-retest_data_July_2014/brain_data/Subject_1/T1_14.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan15	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan15	test-retest_data_July_2014/brain_data/Subject_1/T1_15.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan16	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan16	test-retest_data_July_2014/brain_data/Subject_1/T1_16.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan17	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan17	test-retest_data_July_2014/brain_data/Subject_1/T1_17.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan18	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan18	test-retest_data_July_2014/brain_data/Subject_1/T1_18.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan19	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan19	test-retest_data_July_2014/brain_data/Subject_1/T1_19.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan20	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan20	test-retest_data_July_2014/brain_data/Subject_1/T1_20.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan21	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan21	test-retest_data_July_2014/brain_data/Subject_1/T1_21.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan22	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan22	test-retest_data_July_2014/brain_data/Subject_1/T1_22.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan23	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan23	test-retest_data_July_2014/brain_data/Subject_1/T1_23.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan24	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan24	test-retest_data_July_2014/brain_data/Subject_1/T1_24.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan25	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan25	test-retest_data_July_2014/brain_data/Subject_1/T1_25.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan26	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan26	test-retest_data_July_2014/brain_data/Subject_1/T1_26.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan27	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan27	test-retest_data_July_2014/brain_data/Subject_1/T1_27.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan28	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan28	test-retest_data_July_2014/brain_data/Subject_1/T1_28.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan29	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan29	test-retest_data_July_2014/brain_data/Subject_1/T1_29.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan30	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan30	test-retest_data_July_2014/brain_data/Subject_1/T1_30.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan31	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan31	test-retest_data_July_2014/brain_data/Subject_1/T1_31.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan32	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan32	test-retest_data_July_2014/brain_data/Subject_1/T1_32.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan33	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan33	test-retest_data_July_2014/brain_data/Subject_1/T1_33.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan34	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan34	test-retest_data_July_2014/brain_data/Subject_1/T1_34.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan35	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan35	test-retest_data_July_2014/brain_data/Subject_1/T1_35.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan36	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan36	test-retest_data_July_2014/brain_data/Subject_1/T1_36.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan37	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan37	test-retest_data_July_2014/brain_data/Subject_1/T1_37.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan38	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan38	test-retest_data_July_2014/brain_data/Subject_1/T1_38.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan39	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan39	test-retest_data_July_2014/brain_data/Subject_1/T1_39.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject1Scan40	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject1Scan40	test-retest_data_July_2014/brain_data/Subject_1/T1_40.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan1	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan1	test-retest_data_July_2014/brain_data/Subject_2/T1_01.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan2	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan2	test-retest_data_July_2014/brain_data/Subject_2/T1_02.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan3	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan3	test-retest_data_July_2014/brain_data/Subject_2/T1_03.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan4	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan4	test-retest_data_July_2014/brain_data/Subject_2/T1_04.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan5	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan5	test-retest_data_July_2014/brain_data/Subject_2/T1_05.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan6	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan6	test-retest_data_July_2014/brain_data/Subject_2/T1_06.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan7	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan7	test-retest_data_July_2014/brain_data/Subject_2/T1_07.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan8	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan8	test-retest_data_July_2014/brain_data/Subject_2/T1_08.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan9	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan9	test-retest_data_July_2014/brain_data/Subject_2/T1_09.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan10	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan10	test-retest_data_July_2014/brain_data/Subject_2/T1_10.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan11	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan11	test-retest_data_July_2014/brain_data/Subject_2/T1_11.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan12	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan12	test-retest_data_July_2014/brain_data/Subject_2/T1_12.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan13	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan13	test-retest_data_July_2014/brain_data/Subject_2/T1_13.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan14	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan14	test-retest_data_July_2014/brain_data/Subject_2/T1_14.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan15	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan15	test-retest_data_July_2014/brain_data/Subject_2/T1_15.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan16	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan16	test-retest_data_July_2014/brain_data/Subject_2/T1_16.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan17	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan17	test-retest_data_July_2014/brain_data/Subject_2/T1_17.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan18	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan18	test-retest_data_July_2014/brain_data/Subject_2/T1_18.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan19	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan19	test-retest_data_July_2014/brain_data/Subject_2/T1_19.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan20	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan20	test-retest_data_July_2014/brain_data/Subject_2/T1_20.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan21	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan21	test-retest_data_July_2014/brain_data/Subject_2/T1_21.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan22	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan22	test-retest_data_July_2014/brain_data/Subject_2/T1_22.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan23	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan23	test-retest_data_July_2014/brain_data/Subject_2/T1_23.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan24	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan24	test-retest_data_July_2014/brain_data/Subject_2/T1_24.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan25	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan25	test-retest_data_July_2014/brain_data/Subject_2/T1_25.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan26	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan26	test-retest_data_July_2014/brain_data/Subject_2/T1_26.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan27	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan27	test-retest_data_July_2014/brain_data/Subject_2/T1_27.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan28	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan28	test-retest_data_July_2014/brain_data/Subject_2/T1_28.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan29	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan29	test-retest_data_July_2014/brain_data/Subject_2/T1_29.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan30	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan30	test-retest_data_July_2014/brain_data/Subject_2/T1_30.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan31	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan31	test-retest_data_July_2014/brain_data/Subject_2/T1_31.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan32	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan32	test-retest_data_July_2014/brain_data/Subject_2/T1_32.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan33	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan33	test-retest_data_July_2014/brain_data/Subject_2/T1_33.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan34	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan34	test-retest_data_July_2014/brain_data/Subject_2/T1_34.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan35	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan35	test-retest_data_July_2014/brain_data/Subject_2/T1_35.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan36	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan36	test-retest_data_July_2014/brain_data/Subject_2/T1_36.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan37	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan37	test-retest_data_July_2014/brain_data/Subject_2/T1_37.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan38	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan38	test-retest_data_July_2014/brain_data/Subject_2/T1_38.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan39	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan39	test-retest_data_July_2014/brain_data/Subject_2/T1_39.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject2Scan40	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject2Scan40	test-retest_data_July_2014/brain_data/Subject_2/T1_40.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan1	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan1	test-retest_data_July_2014/brain_data/Subject_3/T1_01.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan2	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan2	test-retest_data_July_2014/brain_data/Subject_3/T1_02.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan3	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan3	test-retest_data_July_2014/brain_data/Subject_3/T1_03.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan4	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan4	test-retest_data_July_2014/brain_data/Subject_3/T1_04.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan5	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan5	test-retest_data_July_2014/brain_data/Subject_3/T1_05.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan6	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan6	test-retest_data_July_2014/brain_data/Subject_3/T1_06.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan7	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan7	test-retest_data_July_2014/brain_data/Subject_3/T1_07.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan8	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan8	test-retest_data_July_2014/brain_data/Subject_3/T1_08.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan9	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan9	test-retest_data_July_2014/brain_data/Subject_3/T1_09.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan10	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan10	test-retest_data_July_2014/brain_data/Subject_3/T1_10.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan11	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan11	test-retest_data_July_2014/brain_data/Subject_3/T1_11.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan12	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan12	test-retest_data_July_2014/brain_data/Subject_3/T1_12.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan13	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan13	test-retest_data_July_2014/brain_data/Subject_3/T1_13.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan14	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan14	test-retest_data_July_2014/brain_data/Subject_3/T1_14.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan15	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan15	test-retest_data_July_2014/brain_data/Subject_3/T1_15.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan16	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan16	test-retest_data_July_2014/brain_data/Subject_3/T1_16.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan17	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan17	test-retest_data_July_2014/brain_data/Subject_3/T1_17.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan18	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan18	test-retest_data_July_2014/brain_data/Subject_3/T1_18.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan19	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan19	test-retest_data_July_2014/brain_data/Subject_3/T1_19.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan20	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan20	test-retest_data_July_2014/brain_data/Subject_3/T1_20.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan21	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan21	test-retest_data_July_2014/brain_data/Subject_3/T1_21.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan22	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan22	test-retest_data_July_2014/brain_data/Subject_3/T1_22.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan23	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan23	test-retest_data_July_2014/brain_data/Subject_3/T1_23.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan24	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan24	test-retest_data_July_2014/brain_data/Subject_3/T1_24.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan25	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan25	test-retest_data_July_2014/brain_data/Subject_3/T1_25.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan26	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan26	test-retest_data_July_2014/brain_data/Subject_3/T1_26.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan27	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan27	test-retest_data_July_2014/brain_data/Subject_3/T1_27.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan28	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan28	test-retest_data_July_2014/brain_data/Subject_3/T1_28.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan29	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan29	test-retest_data_July_2014/brain_data/Subject_3/T1_29.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan30	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan30	test-retest_data_July_2014/brain_data/Subject_3/T1_30.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan31	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan31	test-retest_data_July_2014/brain_data/Subject_3/T1_31.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan32	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan32	test-retest_data_July_2014/brain_data/Subject_3/T1_32.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan33	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan33	test-retest_data_July_2014/brain_data/Subject_3/T1_33.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan34	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan34	test-retest_data_July_2014/brain_data/Subject_3/T1_34.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan35	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan35	test-retest_data_July_2014/brain_data/Subject_3/T1_35.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan36	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan36	test-retest_data_July_2014/brain_data/Subject_3/T1_36.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan37	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan37	test-retest_data_July_2014/brain_data/Subject_3/T1_37.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan38	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan38	test-retest_data_July_2014/brain_data/Subject_3/T1_38.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan39	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan39	test-retest_data_July_2014/brain_data/Subject_3/T1_39.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
Subject3Scan40	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	Subject3Scan40	test-retest_data_July_2014/brain_data/Subject_3/T1_40.nii	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
ADNIPhantom	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	ADNIPhantom1	test-retest_data_July_2014/phantom_data/ADNI_phantom/IM-0001-45604432-0001.dcm	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
ACRPhantom	ADNI-recommended T1-weighted data collection protocol	accelerated sagittal 3D IR-SPGR, 27 cm FOV, 256 x 256 matrix slice, 1.2 mm slice thickness, standard 8-channel phased array head coil, TR: 7.3 ms, TE: 3 ms, TI: 400 ms, flip angle: 11 deg., acquisition time: 5min 37s 	GE MR750 3 T scanner (software version DV22.0_V02_1122.a , XRMB gradient set) 	General Electric	3 T	ACRPhantom1	test-retest_data_July_2014/phantom_data/ACR_phantom/IM-0001-45604432-0001.dcm	FigShare	929651	http://dx.doi.org/m9.figshare.929651						"Patient data including scan time of day, patient weight during scan, and dates of scans are recorded in ""scan_number_vs_time_of_day.xlsx"", ""scan_number_vs_subject_weight"", and ""scan_schedule.xlsx"" and can be found with the FigShare record"
